other
Products
Home

Products

DC/DC converter

GST-H150S18-M

GST-H150S18-M

  • Brand:

    POWERLD
  • Item NO.:

    GST-H150S18-M
  • Wattage (W):

    150
  • Input:

    176-264Vac
  • Output:

    18
  • PFC:

    N
  • Conformal Coating:

    N
  • Approval:

    N
  • Dimension:

    450*300*250mm
  • Product Detail

SPECIFICATION                                                      


MODEL

GST-H150S18-M

OUTPUT

DC Output

18V

Rated Current

8.33A

Current Range     Note 1

0~8.33A

Ripple and Noise   Note 2

0Ta50

180mVpp

-25Ta0

400mVpp

Voltage ADJ.  Range

17~20V

Voltage Accuracy

±2.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

Line Regulation

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load Regulation

±2.0%

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

Set-up Time

≤4S(220Vac input, Full load)

Hold up Time

≥16mS(220Vac input, Full load)

Temperature Coefficient

±0.03%/℃

Overshoot and Undershoot

<5.0%

INPUT

Voltage Range  

176-264Vac

Frequency Range

47Hz--63Hz

Efficiency ( Typical)@25℃

≥84%@Typ.

AC Current (max.)

2.5A (220Vac)

Inrush Current (Typical)

50A@220Vac Cold start

Leakage Current

Input—output:<0.25mA     Input—PG:<3.5mA

PROTECTION

Over Load

8.75~12.5A, hiccup mode, auto recovery

Over power

157.5~225W, hiccup mode, auto recovery

Short Circuit

Long-term mode, auto recovery

ENVIRONMENT

Operating amb. Temp. & Hum.

-25~50;  20%~90%RH  No condensing;( refer to the derating curve)

Storage Temp. & Hum.

-40℃~85℃;  10%~95%RH  No condensing

SAFETY &EMC  

(Note3)

Safety Standards

GB4943/EN60950

Withstand Voltage

Primary-Secondary: 3.0KVac/10mA.Primary-PG:1.5KVac/10mA. Secondary-PG: 0.5KVDC/10mA.

Isolation Resistance

10M ohms

EMS Immunity

Compliance to EN61000-4-2,4,5,8,11;

OTHERS

MTBF (MIL-HDBK-217F)

More than 200,000Hrs (25℃, Full load)

Dimension  (L*W*H)

199×99×38mm

Packing

20PCS/CTN, 15.2kgs, 0.053CBM

Cooling method

Cooling by free air convection

NOTE

1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.

2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor.

3.        The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives.

Our industrial power supply products enjoy great popularity among customers for our good quality and competitive price.We also welcome OEM and ODM orders.

Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #
  • If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!

Related Products
PSF-550S industry power supply
PSF-550S

Ø  Universal input 80~264Vac or 113~370Vdc Ø  Built-in Active PFC, PF≥0.95 Ø  400W convention, 550W forced air Ø  No load power consumption<0.5W by PS­_ON/OFF Ø  Extremely low leakage current≤0.1mA Ø  12V/0.5A fan supply Ø  Output protections: SCP/OVP/OCP/OTP Ø  Wide operating ambient temperature (-40℃~70℃) Ø  Operating altitude up to 5000m Ø  5’’*3’’ Compact size Ø  Meet medical safety(2*MOPP) Ø  Fit for Class I & Class II configuration Ø  3 years warranty MODEL PSF-550S-12 PSF-550S-24 PSF-550S-36 PSF-550S-48 PSF-550S-54 OUTPUT DC Output 12V 24V 36V 48V 54V Rated Current (Convection) 33.4A 16.7A 11.1A 8.34A 7.4A Rated Current (16CFM forced air) 41.7A 22.9A 15.3A 11.46A 10.2A Rate Power(Convection) 400.8W 400.8W 399.6W 400.3W 399.6W Rate Power(16CFM forced air) 500.4W 549.6W 550.8W 550W 550.8W Ripple and Noise @25℃ Note 2 ≤200mVp-p Voltage ADJ.  Range 11.4~12.6V 22.8~25.2V 34.2~37.8V 45.6~50.4V 50.5~54V Voltage Accuracy ±2% Line Regulation ±1.0% Load Regulation ±1.0% Set-up Time ≤1.0S (230Vac input, Full load) Hold up Time 8mS @115/230Vac input   Full load Temperature Coefficient ±0.02%/℃ Overshoot <5.0% INPUT Voltage Range   Note 3 80~264Vac or 113~370Vdc Rated input voltage range 100~240Vac Frequency Range 47Hz-63Hz Efficiency ( Typical) 93.5% 94% 94% 94% 94% Power Factor(Typical) ≥0.95 @ 100~240Vac  full load AC Current (max.) <6.5A Inrush Current (Typical) <40A@115Vac ; <80A @ 230Vac      Cold start Leakage Current Touch current ≤0.1mA   @ ac input to dc output PROTECTION Over Current 110%~150%, hiccup mode, recovers automatically after fault condition is removed Over Voltage 110%~130%, constant voltage, recovers automatically after fault condition is removed Over temperature Shut down o/p voltage, recovers automatically after temperature goes down Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -40℃~70℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing Operating altitude (Note 3) 5000 meters SAFETY &EMC   (Note 4) Safety Standards IEC62368 / IEC60601 Withstand Voltage Primary-Secondary: 4KVac/5mA; Primary to PG: 2.0KVac/5mA; Secondary-PG: 1.5Vac/5mA Isolation Resistance 100M ohms EMI Conduction&Radiation Compliance to EN55032 Class B(Class I); Harmonic Current Compliance to EN61000-3-2, Class A EMS Immunity Compliance to EN61000-4-2,3,4,6,11; OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃) 5V standby 5V/1A,tolerance ±2%, ripple : 120mVp-p(max.) PS_ON/OFF Power ON: PS-ON/OFF, "Hi" or " > 2 ~ 5V" ; Power OFF: PS-ON/OFF,"Low" or " < 0 ~ 0.5V" POWER GOOD / POWER FAIL 500ms>PG>10ms ; The TTL signal goes high with 10ms to 500ms delay after power set up ; The TTL signal goes low at least 1ms before Vo below 90% of rated value Dimension  (L*W*H) 127*76.2*40.5mm (5’’*3’’*1.59’’ inch) Packing TBD Cooling method 400W free air convection; 550W with 16CFM forced air NOTE 1.     All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.     The ambient temperature derating of 0.5℃/100m for operating altitude higher than 2000m. 4. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 

DG-120-X  din rail power supply
DG-120-X

Ø  Universal AC input range(85~264Vac) Ø  Support 1+1 or N+1 redundant system(suggest to use redundancy modules.) Ø  Built-in active PFC,PF>0.95 Ø  High efficiency up to 92% Ø  Built-in current sharing function Ø  Built-in current limiting circuit Ø  Output protections: OVP/OLP/SCP/OTP Ø  Wide operating ambient temp (-25℃~70℃) Ø  150%(180W) peak load capacity Ø  Easy Fuse Tripping due to High Overload Current Ø  Excellent Partial Load Efficiency Ø  Built-in DC OK relay contact Ø  Can be installed on TS-35/7.5 or TS-35/15 Ø  100% full load burn-in test Ø  Suitable for critical applications Ø  Ultra-slim,32mm width Ø  3 years warranty SPECIFICATION MODEL DG-120-12 DG-120-24 DG-120-48 OUTPUT DC Output 12V 24V 48V Rated Current 10A(pls refer to derating curve) 5A 2.5A CurrentRange Note  0~10A 0~5A 0~2.5 Ripple and Noise  Note 2 0~70℃ ≤100mV ≤120mV ≤240mV -25℃ ≤200mV ≤240mV ≤240mV Voltage ADJ. Range 12~14V 24~28V 48~56V Voltage Accuracy ±1.0% Line Regulation ±0.5% Load Regulation ±1.0% Set-up Time <250mS@230Vac ; <500mS@100Vac Hold up Time ≥20mS(230Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT VoltageRange   85Vac~264Vac, 127Vdc-360Vdc FrequencyRange 47Hz~63Hz Power Factor (typical) 0.99/100Vac    0.95/230Vac Efficiency ( Typical) 89.5% 91% 92% AC Current (max.) <1.5 A/100Vac       <0.65A/230Vac Inrush Current (Typical) <30A/100Vac     <60A/230Vac  Cold start Leakage Current Input—output:<0.25mA    Input—PG:<3.5mA PROTECTION Over Load 110%~150% of rated current, Constant current limiting for some time(150% of rated current, last 3S) then PS stop working for 7S,after 7S,if the load <=rated current, PS will work normally, auto recovery Over voltage 15~18V 29~33V 58~65V Protection type: Hiccup mode, Auto recovery Over temperature 100±5℃, detect on heat sink of power transistor; shut down O/P, auto recovery after temperature goes down. Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃; 20%~90%RH No condensing Storage Temp. & Hum. -40℃~85℃; 5%~95%RH No condensing SAFETY &EMC Note 3 Safety Standards meet UL508, UL60950, EN60950 Withstand Voltage Primary-Secondary:3.0KVac;≤10mA .Primary-PG:2.5KVac;≤10mA. Secondary-PG:0.5KVac≤10mA. Isolation Resistance 10M ohms EMC Emission Compliance to EN55022, EN55024, FCC PART 15 Class B Harmonic Current Compliance to EN61000-3-2, CLASS A EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 300,000Hrs (25℃, Full load) Dimension (L*W*H) 124*119*32mm Packing 28pcs/CTN,18.02Kgs, 0.04cbm Cooling method Cooling by free air convection Additional function Power boost 150% of rated current DC OK V On: when output voltage is up to 90% of rated output voltage V Off: when output voltage is down to 80% of rated output voltage DC OK relay contact rating Max 30V/1Aor 60V/0.3Aor 30Vac/0.3AResistive load Parallel function support NOTE 1. All parameters NOT specially mentioned are measured at rated input, rated load and25℃of ambient temperature. 2. Measured at 20MHz of bandwidth by using a12”twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies” on https://www.powerld.com. We have a complete DIN rail power supply product catalog, providing reliable quality DIN rail power supply and affordable prices, fast delivery, customizable, please leave a message for consultation.

PD-35-X Power Supply
PD-35-X

Ø  No Load power consumption<0.5W Ø  Universal AC input range Ø  Miniature size, high power density, high efficiency, long life and high reliability Ø  Withstand 300VA surge input for 5 sec. Ø  Output protections: OLP/OVP/SCP Ø  Wide operating ambient temp (-25℃~70℃),100% @50℃& 60%@70℃ Ø  Operating altitude up to 5000M Ø  All using 105℃ long life electrolytic capacitors. Ø  100% full load burn-in test Ø  Easy assembling from top side Ø  PCB soldering side with conformal coating Ø  Suitable for critical applications Ø  3 years warranty    SPECIFICATION                                              MODEL PD-35-5 PD-35-12 PD-35-15 PD-35-24 PD-35-48 OUTPUT DC Output 5V 12V 15V 24V 48V Rated Current 6A 3A 2.4A 1.5A 0.76A Current Range      0~6A 0~3A 0~2.4A 0~1.5A 0~0.76A Ripple and Noise   Note 2 0~70℃ <50mV <80mV <120mV <120mV <180 mV -25~0℃ <80mV <180mV <200mV <200mV <240mV Voltage ADJ.  Range 4.75V-5.5V 11.4V-13.2V 14.25V-16.5V 22.8V-26.4V 45.6V-52.8V Voltage Accuracy ±3.0% ±3.0% ±3.0% ±3.0% ±3.0% Line Regulation ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% Load Regulation ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% Set-up Time <1S (230Vac input, Full load); Hold up Time >20mS(230Vac input, Full load); >10mS(120Vac input, Full load) Temperature Coefficient ±0.03%/℃ Overshoot and Undershoot <5.0% INPUT Voltage Range   90Vac~264Vac,127~370Vdc Frequency Range 47Hz~63Hz Efficiency ( Typical) 115Vac input 79% 83% 85% 86% 87% 230Vac input 80% 84% 86% 87% 88% AC Current (max.) <1A(max) Inrush Current (Typical) <50A@230Vac     Cold start Leakage Current Input—output:<3.5mA     Input—PG:<0.25mA PROTECTION Over Load 105%~150% of rated output current, constant power,auto recovery Over Voltage 105%~150% of rated output voltage, Constant Voltage Short Circuit Long-term mode, auto recovery ENVIRONMENT Operating amb. Temp. & Hum. -25℃~70℃;  20%~90%RH  No condensing (refer to the derating curve) Storage Temp. & Hum. -40℃~85℃;  10%~95%RH  No condensing SAFETY &EMC Note 3 Safety Standards UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 Withstand Voltage Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. Isolation Resistance ≥100M ohms EMC Emission Compliance to EN55022,EN55024 ClassB Harmonic Current Compliance to EN61000-3-2,-3 EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11;EN55024,EN61000-6-2 heavy industry level OTHERS MTBF (MIL-HDBK-217F) More than 200,000Hrs (25℃, Full load) Dimension  (L*W*H) 101.6×63.5×33mm Packing 60PCS/CTN, 15.18KGS, 0.06CBM Cooling method Cooling by free air convection NOTE 1.     All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25℃ of ambient temperature. 2.     Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 3.        The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives. 4.        Powerld offer accessories for Din-35 rail bar. Please contact sales staff for details. Quality industrial power supply products, excellent service, hope to establish the long-term business relationship with you.

#

Copyright © 2024 Powerld Enterprises Co.,Ltd.. All Rights Reserved. 粤ICP备12040476号

IPv6 network supported

top

Leave A Message

Leave A Message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

  • #
  • #
  • #